Product Overview
The JKESS Battery Kit (Energy Storage Cabinet) is a power storage device featuring stable performance and broad compatibility.
It is compatible with both mainstream 51.2V battery packs, enabling flexible integration with power systems and charging devices operating under different voltage standards. Meanwhile, it offers significant advantages in cell compatibility, supporting combinations of 280Ah and 314Ah cells, allowing flexible selection of cell configurations based on actual power load requirements and cost budgets.
In terms of structural specifications, it features a vertical design with wheels for easy mobility and transportation. The battery casing is constructed from galvanized steel plate. The surface galvanization treatment endows the steel plate with excellent rust and corrosion resistance, effectively protecting against harsh environments such as humidity and dust. The steel substrate ensures structural strength, providing reliable physical protection for internal battery components against minor impacts.
Product Highlights
Professional Integration Platform: Specifically designed for 15/16kWh lithium iron phosphate (LiFePO4) battery systems, providing a compatible mounting platform for both the battery and the BMS.
Robust Protection: The structured design enables centralized storage and fixation, minimizing interference and damage from external factors such as impacts, dust, and humidity.
Easy Mobility: The vertical design maximizes vertical space utilization, and the bottom rollers employ rolling friction instead of sliding friction, enabling single-person positioning adjustments without requiring lifting equipment.
Advanced BMS Safety: Equipped with a Battery Management System that continuously monitors cell voltage, temperature, and charge/discharge currents to prevent overcharging, overdischarging, overheating, and short circuits.

Advanced Battery Management: Equipped with JK V19 Smart BMS
At the heart of this battery kit is the renowned JK V19 Battery Management System (BMS). Designed for DIY enthusiasts and professional solar setups, it provides top-tier safety and performance for your 16S LiFePO4 battery pack.
Why choose JK V19 BMS?
Intelligent Active Balancing: Unlike passive balancers, the JK V19 actively transfers energy between cells, ensuring all 16 cells remain perfectly balanced. This maximizes your battery's lifespan and usable capacity.
Real-Time App Monitoring: Built-in Bluetooth allows you to connect directly to your smartphone. Monitor cell voltages, temperatures, state of charge (SOC), and adjust parameters in real-time via the dedicated JK BMS App.
Comprehensive Protection: Continuously monitors cell voltage, current, and temperature to prevent overcharging, over-discharging, overcurrent, and short circuits.
Multiple Communication Interfaces: Supports CAN, RS485, and RS232 protocols, ensuring seamless communication and high compatibility with mainstream inverters (e.g., Victron, Growatt, Deye).
Plug & Play Integration: The BMS is perfectly matched with the kit's wiring harness and LCD screen, making the installation process smoother and safer.
Port Description
| Project Name | Parameter Declaration |
|---|---|
| Nominal Voltage | 51.2 V (= 3.2 V × 16 strings) |
| External Dimensions (L×W×H) |
819×416×285 mm (assembled) 845×485×220 mm (split) |
| Total Weight | Net weight: 21.5 kg; Weight including cardboard box: 26.5 kg |
| Communication Interface | CAN / RS485 interface installation position |
| Shell Material | Alufer |
| Levels of Protection | IP55 (default) / Customizable IP67 |
| Surface Preparation | Spray painting / Anodizing / Electroplating |
| Thermal Design | Natural air duct / Optional fan installation position |
| Operating Temperature Range | -20℃ ~ +60℃ |
| Storage Temperature Range | -40℃ ~ +70℃ |
| Seismic Resistance Level | IEC 61427 standard |


Internal Dimensions & Layout
The kit provides a well-organized layout for the entire battery system, facilitating subsequent maintenance, inspection, and management. It includes an Epoxy board to provide insulation and support for subsequent cell installation.
Port Description
1. Positive terminal: Positive pole
2. Negative terminal: Negative terminal
3. DC circuit breaker: DC circuit breaker
4. Switch: Switch
5. RST: Reduction contact
6. ADD: Communication dial-up number
7. DRY: Used to set the trigger conditions for the protection board dry contact alarm
8. RUN/ALM: Alert Indicator
9. SOC: The number of bulbs indicates the percentage of energy consumption
10. RS485 Interface -1: Communication Interface (Connecting to the Inverter)
11. CAN: Communication Interface (Connecting to the Inverter)
12. RS232CI: (Communication Interface)
13. RS485 Interface -2: Communication interface (battery connector, when connecting multiple batteries in parallel)

Applicable Scenes
Home Energy Storage: Integrated with solar power systems for electricity storage, providing power for daily household use or emergency backup during power outages.
Small-scale Commercial and Industrial Facilities: Functioning as backup power sources to ensure uninterrupted operation of supermarkets, restaurants, and similar establishments.
Outdoor Operations: Provides power support for equipment used in field exploration and construction camps.
Small Communication Base Station: Serving as a supplementary backup power source for core equipment in case of main power failure.
RV Camping: Provides power for interior lighting, refrigerators, and small appliances in RVs.
Medical Clinic: Serving as a backup power supply for small medical devices (such as portable oxygen concentrators and monitors).
Agricultural Greenhouse: Provides power for small ventilation systems, lighting systems, and temperature/humidity sensors.
Assembly Steps
1. Preparation: Ensure you have purchased LiFePO4 cells that meet the kit specifications. Prepare tools such as a screwdriver, wrench, and multimeter. Select a safe, dry, well-ventilated work area.
2. Install the Battery Casing: Place the base shell on a stable workbench, sequentially install the front bracket and two top brackets, and secure them with screws. Install the front panel.
3. Cell Mounting & Insulation: Install the epoxy resin board at designated positions within the base shell. Place the prepared battery cells on the board, ensuring correct polarity. Insert EVA strips between the cells for cushioning and enhanced insulation.
4. Connect the Battery Cell: Connect each cell in series using 15 flexible strips. Use a multimeter to measure the voltage at each connection point to verify correctness.
5. Install BMS & Components: Connect the 48V 16S BMS cable and two additional BMS cables to the corresponding interfaces. Install the LCD screen and four button caps.
6. Install Terminals & Handle: Install four battery terminals (P+ and P-) and the handle on the battery housing.
7. Check and Debug: Carefully inspect the entire assembly. Use a multimeter to conduct a comprehensive measurement, checking the total voltage, individual cell voltages, BMS function, and LCD screen display.
(Note: The edges of sheet metal components must be deburred. The grounding terminal must be reliably connected to the enclosure, grounding resistance ≤ 0.1Ω).
Packing List
Transportation, Storage & Maintenance
Transportation: The battery case is heavy; handle it using pulleys/forklifts or with two-person teamwork. When storing the empty case, avoid stacking heavy objects on top.
Storage: Store in a dry indoor environment, away from direct sunlight or moisture exposure.
Maintenance:
1. Check metal sheet components for deformation and corrosion every 6 months.
2. Wipe the surface with a dry cloth and avoid corrosive solvents.
3. Tighten bolts annually to the specified torque.
⚠️ Security Warning
1. Installation: When installing the internal battery and BMS, ensure all external power sources are disconnected. Do not arbitrarily modify the internal structure of the enclosure.
2. Usage: It is strictly prohibited to place the box near flammable or explosive materials. If any unusual odors, smoke, or abnormal noises are detected, immediately disconnect all power supplies and contact professionals. Do not insert metal objects into the box.
3. Maintenance: Wear protective equipment such as insulating gloves during internal maintenance. Direct water flushing of the tank interior is prohibited. Impact, trampling, or overloading heavy objects onto the container are strictly prohibited.