Battery Configuration
 1P16S
Nominal Voltage
 51.2V
Working Voltage Range
 42V~58.4V
Nominal Capacity
 100Ah
Nominal Power
 5.12KWh95%DOD
Standard Charging/Discharging
Current
 50A @25±2
Maximum Charging Current
 100A@25±2
Maximum Discharging Current
 
 100A @25±2
Working Ambient Temperature
 040(Charge)  /   -1040(Discharge)
Storage Temperature & Humidity
 -10~35(withi 1 month storage)
 25±2(within 3 months storage)
 65%±20%RH
Size (L x W x H
 (563)×(399)×(162)mm
Weight 
 48Kg±3kg
Cycling Lifespan
 6000 cycles @25
 50A Charging/discharging current 80% DOD
IP Rate
 IP 2X
Communication
 CAN or RS485
Altitude
 0-3000m
Humidity Range
 5~80%

C16-cell battery voltage sampling test, with deviation of ±20mV.  Battery and ambient temperature detection: 4 battery temperature sensors, 1 ambient temperature sensor, and 1 MOS temperature sensor, with a deviation of ±2°C. 

Battery capacity and cycles: Complete a full charge/discharge cycle to set the actual capacity. The remaining capacity of the battery is monitored with a capacity estimation accuracy within 5% deviation. Additionally, charge and discharge cycle times as well as full charge and discharge cycle times are configurable. 

Intelligent cell balancing: The charging and static balancing strategies can be set flexibly to effectively extend the service life.

Communication port: PC or smart front-end can monitor battery pack data, control operation and set parameters through commands such RIMDIN 51.2V 100AH LIFEPO4 BATTERY PACK was telemetry, remote signaling, remote adjustment, and remote control. The communication protocol conforms to the requirements of YD/T 1363.3, and realizes cascade communication at the same time.  

History data recording, saving and reading: Battery condition and alarm information will be recorded and save in real time when there is abnormality in the battery. A maximum of 500 history failure data can be stored. 

Battery management system parameter setting: Battery management system parameters includes cell over-voltage/under-voltage, battery total voltage over-voltage/under-voltage, charging/discharging over-current, battery high/low temperature, battery capacity, working mode, charging/discharging current limiting and so on. They can be
set in the battery monitor system.

Working mode: Working modes including charging/discharging current limiting, fixed voltage output, direct output and so on. 
 

Multiple protection functions: Hardware protection, battery protection, high/low temperature protection, output short-circuit protection and so on .